Hybrid Inverter 11kW
- 1.5× MPPT Oversizing
- Dual Start Activation (AC / PV)
- Dual AC Outputs with Smart Load Management
- 27A MPPT Input Current
- 2-year warranty/3-year warranty (optional) / 5-year service
- Parallel Connection: up to 6 Single Phase or 9 Three Phase
| Model | S2(11kW) | ||
|---|---|---|---|
| Battery Data | |||
| Battery Type | Lithium-ion & Lead-acid | ||
| Rated Battery Voltage (Vdc) | 48 | ||
| Battery Voltage Range (Vdc) | 40~60 | ||
| Max. Charge/Discharge Current (A) | 150/220 | ||
| Forced Wake-up by PV | YES | ||
| PV Input | |||
| Max. MPPT Input Power (W) | 2×8250 | No. Of MPPT/ Strings Per MPPT | 2/2 |
| Max. Input Voltage (Vdc) | 500 | Max Input Current Per MPPT (A) | 27 |
| Rated Input Voltage (Vdc) | 370 | Max. Short Circuit Current Per MPPT (A) | 35A |
| MPPT Voltage Range (Vdc) | 60~450 | ||
| Grid Input | |||
| Rated Grid Voltage (Vac) | 220/230/240±5% | Max Input Current (A) | 60 |
| Voltage Input Range (Vac) | 90~280 | Total Harmonic Distortion (THDi) | <3% (of nominal power) |
| Rated Grid Frequency (Hz) | 50 / 60 | ||
| Backup Data | |||
| Rated AC Output Power (W) | 11000 | Rated Output Frequency (Hz) | 50/60±0.1% |
| Rated Output Current (A) | 48 | Total Harmonic Distortion (THDi) | <3% |
| Overload Capability | 10s@105%~120%;5s@121%~200%;100ms@>200% | ||
| Switch Time (ms) | 10ms for Computer Equipment, 20ms for Household Equipment | ||
| Efficiency | |||
| Max Inverter Efficiency | 97.00% | MPPT Tracking Efficiency | 99.90% |
| Protection | |||
| Integrated | DC Polarity Reverse Connection Protection,AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Power Network Monitoring, Earth Fault Detection,Surge protection level | ||
| Surge Protection | TYPE II (DC), TYPE II (AC) | ||
| Over Voltage Category | OVC II (DC), OVC III (AC) | ||
| General Data | |||
| Operating Temperature (°C) | -10~+55 | Cooling | Smart cooling |
| Dimensions [W*H*D] (mm) | 420*450*105 | Altitude (m) | ≤3000 |
| Weight (kg) | 15.5 | Protection Level | IP21 |
| Inverter Topology | Non-isolated | Warranty | 2 Years |
| Communication Interfaces | RS232 / RS485 / CAN / Dry contact/ External battery NTC/Parallel communication/WIFI(optional) | ||
| Standard | |||
| Safety Standards | IEC 62109-1:2010, EN 62109-1:2010, IEC 62109-2:2011, EN 62109-2:2011 | ||
| EMC Standards | EN IEC 61000-6-1:2019;EN IEC 61000-6-3:2021;EN IEC 61000-3-11:2019;EN61000-3-12:2011 | ||
| Efficiency Standard | IEC 61683:1999 | ||
The Core of Light.
The Dawn of Energy.
The Dawn of Energy.