| Model | S4(8kW) | ||
|---|---|---|---|
| Battery Data | |||
| Battery Type | Lithium-ion & Lead-acid | ||
| Rated Battery Voltage (Vdc) | 48 | ||
| Battery Voltage Range (Vdc) | 40~60 | ||
| Max. Charge/Discharge Current (A) | 165/165 | ||
| Forced Wake-up by PV | YES | ||
| PV Input | |||
| Max. MPPT Input Power (W) | 15000 | MPPT Voltage Range (Vdc) | 60~450 |
| Max. Input Voltage (Vdc) | 500 | No. Of MPPT/ Strings Per MPPT | 2/1+1 |
| Rated Input Voltage (Vdc) | 370 | Max Input Current Per MPPT (A) | 20+20 |
| Start-Up Voltage (Vdc) | 70 | Max. Short Circuit Current Per MPPT (A) | 27+27 |
| Grid Input/Output | |||
| Rated AC Output Power (W) | 8000 | Rated Grid Frequency (Hz) | 50/60 |
| Maximum Apparent Power (VA) | 8000 | Frequency Range (Hz) | 40-65 |
| Rated Output Current (A) | 36.4/34.8/33.4 | Max Input Current(A) | 50 |
| Rated Grid Voltage (Vac) | 220/230/240±5% | Max Output Current (A) | 50 |
| Voltage Input Range (Vac) | 90~280 | Total Harmonic Distortion (THDi) | <3% |
| GEN | |||
| Rated GEN Voltage (V) | 230 | Rated GEN Input power(V) | 9200 |
| Rated GEN Input current (A) | 40 | ||
| Load Parameter | |||
| Rated Output Power (W) | 8000 | Rated Output Current (A) | 36.4/34.8/33.4 |
| Maximum Apparent Power (VA) | 8000 | Rated Output Voltage (Vac) | 220/230/240±5% |
| Rated Output Frequency (Hz) | 50/60±0.1% | Total Harmonic Distortion (THDv) | 3% |
| Overload Capability | 1min@101-110%;10s@110%~150%;5s@150%~200%;100ms@>200% | ||
| Switch Time (ms) | 4~6ms for Computer Equipment, 20ms for Household Equipment | ||
| Efficiency | |||
| Max Inverter Efficiency | 97.00% | MPPT Tracking Efficiency | 99.90% |
| Protection | |||
| Integrated | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection,AC Output Short Circuit Protection, DC Component Monitoring,Overvoltage Load Drop Protection, Power Network Monitoring, Earth Fault Detection,Surge protection level | ||
| Surge Protection | TYPE II (DC), TYPE II (AC) | ||
| Over Voltage Category | OVC II (DC), OVC III (AC) | ||
| General Data | |||
| Operating Temperature (°C) | -40~+60 (Above 45°C Derating) | Cooling | Smart cooling |
| Humidity (%RH) | 0~100% | Altitude (m) | ≤3000 |
| Dimensions [W*H*D] (mm) | 430*350*177.8 | Protection Level | IP66 |
| Weight (kg) | 15.5 | Display | LED Display/Touchable Display |
| Inverter Topology | Non-Isolated | Warranty | 5 Years |
| Communication | RS485 / CAN / Dry contact/ External battery NTC/Parallel communication/WIFI(Built-in) | ||
| Certification Standard | |||
| Safety Standards | IEC 62109-1:2010, EN 62109-1:2010, IEC 62109-2:2011, EN 62109-2:2011 | ||
| Efficiency Standard | IEC 61683:1999 | ||